Page text (OCR, may contain mistakes)
A/C PERFORMANCE TEST
When the ambient ai
r temperature is low, con-
duct 8 performance test using the following candi-
tions and measuring m
ethods. If measured data are
within the O.K. zone, performance is 0.4.
TEST CONDITION
Door:
Door window:
Hood:
Air control lever postion:
Intake lever position:
Fan lever position:
Air conditioner switch:
TEMP, laver position:
Engine speed:
Intake air temperature:
Compressor discharge
Pressure:
Closed
Closed
Open
“3 (FACE)
REGIRG,
A
ON
Make cold-hot adjustment so intake air temperature (bafore the
blowsr] can be set at 30°C
(86°F). (Rater te ‘HOW TO
MEASURE”. |
1,500 rpm
S0°C (86°F)
1,912 kPa (19.6 kg/cm? , Ziff
psi] (Refer te “HOW TO MEAS-
URE”.
ITEMS TO MEASURE
e Compressor discharge pressure
# Compressor suction pressure
® Outlet temperature
Measure the outlet temperature by inserting a
thermocouple into the connecting port between the cooling unit and heater unit, not
into thé vent in the instrument panel.
intake temperature
Intake humidity
Measure the intake air temperature (wet and
cry bulb} immediately before the blower and
determine the humidity by using the humidity
conversion table.
Performance Chart-B (In the cold climate)
HOW TO MEASURE
When installation of the instruments used for’
measuring the above items, start the engine and.
turn on the air conditioner. Set the engina!
speed at 1,500 rpm and make an adjustment:
with the ternperature jever so as to keep the in-J
take air temperature at 30°C (86°F).
The compressor discharge pressure should be:
raised ta a pressure of 1,912 kPa (19.5 kg/em?,
277 psi) and set at that level by blocking the:
front of the condenser with corrugated paper'
{amount of blockage should be changed:
depending on the outside temperature at that
time).
When the intake air temperature reaches 30°C.
(86°F) and compressor discharge pressurad
1,912 kPa (19.5 kg/cm*, 277 psi}, the abow
listed items should be measured and recorded’
As a standard, measurement is started ten
minutes after the 4/C compressor is angaced,
However, even if the abave conditions are
reached earlier due to the difference in temped
rature, etc., the A/C compressor should be!
operated for at least five minutes.
Ten minutes after starting the A/C compresior,
make sure that the intake relative humidity
drops to below 50% and remains there. Thi
means there is proper recirculation. if it fails tg
do this, check the recirculation system such a
the intake unit for air tightness and the intg
lever for proper operation, After completing
this, measure the above listed items again,
HA-14