Page text (OCR, may contain mistakes)
DESCRIPTION — Refrigeration System
Refrigeration Cycle
REFRIGERANT FLOW
The refrigerant flows in the standard pattern, that is, through the compressor, the condenser, the liquid
tank, through the evaporator, and the compressor.
The refrigerant evaporation through the evaporator coil is controlled by an externally equalized expansion valve, located inside evaporator case.
FREEZE PROTECTION
Under normal operating conditions, when the A/C is switched on, the compressor runs continuously, and
the evaporator pressure, and therefore temperature, is controlled by the V-5 variable displacement
compressor.
If evaporator coil temperature falls below a specified point, the thermo-control amplifier interrupts compressor operation. When evaporator coil temperature rises above the specification, compressor operation will resume. This condition (compressor cycling) indicates a malfunction in the system.
REFRIGERANT SYSTEM PROTECTION
Dual-pressure switch
The refrigerant system is protected against excessively high or low pressure by the dual-pressure
switch, located on the liquid tank. If the system pressure rises above, or falls below the specifications,
the dual-pressure switch opens to interrupt compressor operation.
Fusible plug
Open at temperatures above 105°C (221°F), thereby discharging refrigerant to the atmosphere. If this plug
is melted and opened, check the refrigerant line and replace the liquid tank.
Pressure relief valve
The refrigerant system is also protected by a pressure relief valve, located on the end of compressor.
When the pressure of the refrigerant in the system increases to an abnormal level [more than 3,727 kPa
(38 kg/cm’, 540 psi)], the release port on the pressure relief valve automatically opens and releases
refrigerant into the atmosphere.
Pressure relief High-pressure Low-pressure
valve oe gas liquid
Compressor High-pressure Low-pressure
P verre ray P
liquid gas
ia >
ae
Outside air
wo
Condenser
af Evaporator il
t at
=a
Blower motor
Expansion valve
Fusible plug Dual-pressure switch
SHA459D
HA-9
MA
EM
LC
EF
EC
PE
CL
MT
AY
PD
PA
RA
BR
ST
BF
EL